LCT LAS-C1 / Tension/Compression Load cell/ S- beam/ IP65/ Aluminum / for tensile bench
Description
Model: LAS-C1
Brand: LCT
Capacity: 50,100,200,500 (kg)
Usage: Mainly used for crane scale,hopper scale,tension control,tensile testing etc.
Dimension: 76.2*50.8*18mm
        分享    
    
                            描述                            
                                                        
                                                    Description
Model: LAS-C1
Brand: LCT
Capacity: 50,100,200,500 (kg)
Usage: Mainly used for crane scale,hopper scale,tension control,tensile testing etc.
Dimension: 76.2*50.8*18mm
Features
- S-type load cells
- capacity:50kg,...,500kg
- accuracy:0.05% R.O.
- aluminum construction with surface anodized
- environment protection class:IP65
Applications
- crane scales
- hopper scales
- tensile testing
- test benches
- machine testing
Description
LCT S-type Load Cells have been designed for measuring static and dynamic tensile and compressive forces.
Advantages of LCT S-type Load Cells:
Quick to install thanks to off-center load compensation at the factory (per OIML R60),and you benefit from a new generation of high-precision, S-type load cells. Be it force measurement in machines, test benches and production lines or tests in development: LCT S-type load cells are the reliable and safe choice for precise force measurement - providing compelling benefits for you.
Model LAS-C1 load cells are designed to this “S-type”and manufactured from high quality aluminum alloy of aviation standard. LAS-C1 load cells can be used to measure loads range from 50kg to 500kg with the measuring accuracy of 0.05% R.O.( R.O.=Rated Output) and 2mV/V output signal.
LAS-C1 load cells are mainly used for crane scales,hopper scales,tensile testing,test benches and machine testing.

Electrical Connection


Technical Data
Note
| Rated Capacity | 50, 100, 200, 500 (kg) | 
| Accuracy Class | S | 
| Rated Output | 2.0 ± 5%mV/V | 
| Zero Balance | ±5%R.O. | 
| Input Resistance | 1130±20Ω | 
| Output Resistance | 1000±10Ω | 
| Linearlty Error | ±0.05%R.O. | 
| Repeatability Error | ±0.05%R.O. | 
| Hysteresis Error | ±0.05%R.O. | 
| Creep in 30 Min. | ±0.05%R.O. | 
| Temp.Effect on Output | ±0.05%R.O./10℃ | 
| Temp.Effect on Zero | ±2%R.O./10℃ | 
| Compensated Temp.Range | 0-+40℃ | 
| Excitation,Recommended | 5-12VDC | 
| Excitation,Maximum | 18VDC | 
| Operating Temp.Range | -10-+40℃ | 
| Safe Overload | 150%R.C. | 
| Ultimate Overload | 200%R.C. | 
| Insulation Resistance | ≥2000MΩ(50VDC) | 
| Cable,Length | ø0.6mm× 0.1m * | 
| Protection Class | IP65 | 
Note
- The length of cable can be customized.
 
         
                         
                        
 
                             
                     
                     
                     
                     
                     
                     
                    


 
                 
                